HP P2000 G3 MSA System CLI Reference Guide 257
show ports
Description
Shows information about host ports on both controllers. This command shows the same information
as the
show host-parameters
command.
Syntax
show ports
Output
Ports
Controller ID and port number.
Media
•
FC(P)
: Fibre Channel Point-to-Point (public or private).
•
FC(L)
: Fibre Channel-Arbitrated Loop.
•
FC(-)
: Not applicable, as when the port is disconnected.
•
SAS
: Serial Attached SCSI.
•
iSCSI
: Internet SCSI.
Target ID
Port WWN or IQN.
Status
Whether the port is operational, has a problem, or is disconnected.
Speed (A)
Actual host-port link speed, or blank if not applicable.
Speed (C)
Configured host-port link speed:
•
FC:
Auto
,
8Gb
,
4Gb
, or
2Gb
(Gbit/sec).
•
iSCSI:
Auto
or
1Gb
(Gbit/sec).
•
Blank if not applicable.
Health
•
OK
•
Degraded
•
Fault
•
N/A
Health Reason
If Health is not
OK
, this field shows the reason for the health state.
Health Recommendation
If Health is not
OK
, this field shows recommended actions to take to resolve the health issue.
Topo (C)
FC and SAS only. Configured topology.
Width
SAS only. Number of PHY lanes in the SAS port.
PID
FC only. Primary loop ID, or blank if not applicable.
IP-Ver
iSCSI only. IP version: IPv4 or IPv6.
PIP
iSCSI only. Primary IP address.
PIP-Gateway
iSCSI only. Primary gateway IP address.
Содержание P2000 G3
Страница 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Страница 14: ...14 About this guide ...
Страница 30: ...30 Categorical list of commands ...
Страница 96: ...96 Alphabetical list of commands exit Description Log off and exit the CLI session Syntax exit ...
Страница 159: ...HP P2000 G3 MSA System CLI Reference Guide 159 See also set host parameters show iscsi parameters ...
Страница 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Страница 217: ...HP P2000 G3 MSA System CLI Reference Guide 217 Basetypes drives enclosure list status See also show vdisks ...
Страница 223: ...HP P2000 G3 MSA System CLI Reference Guide 223 Basetypes email parameters status See also set email parameters ...
Страница 230: ...230 Alphabetical list of commands See also clear events set snmp parameters show snmp parameters ...
Страница 288: ...288 Alphabetical list of commands Basetypes snapshots status See also show master volumes show snap pools ...
Страница 292: ...292 Alphabetical list of commands Basetypes system unhealthy component status See also set system ...
Страница 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Страница 338: ...338 Alphabetical list of commands Basetypes remote links See also show remote systems verify remote link ...
Страница 340: ...340 Alphabetical list of commands Basetypes remote links See also show remote systems verify links ...
Страница 424: ...424 XML API basetype properties PROPERTY name utility priority numeric type string 0 PROPERTY OBJECT ...
Страница 469: ...HP P2000 G3 MSA System CLI Reference Guide 469 PROPERTY name status type string OK PROPERTY OBJECT ...
Страница 494: ...494 XML API basetype properties PROPERTY name sample time numeric type string 1329397200 PROPERTY OBJECT ...
Страница 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Страница 510: ...510 XML API basetype properties PROPERTY name reserve type numeric type string 0 PROPERTY OBJECT ...
Страница 524: ...524 Glossary ...
Страница 532: ...532 Index ...