HP P2000 G3 MSA System CLI Reference Guide 389
job-running
string
Job running on the disk, if any.
•
(blank): None.
•
DRSC
: The disk is being scrubbed.
•
EXPD
: The vdisk is being expanded.
•
INIT
: The vdisk is being initialized.
•
RCON
: The vdisk is being reconstructed.
•
VRFY
: The vdisk is being verified.
•
VRSC
: The vdisk is being scrubbed.
job-running-
numeric
string
Numeric equivalents for
job-running
values.
•
0
: None
•
2: INIT
•
3: RCON
•
4: VRFY
•
5: EXPD
•
6: VRSC
•
7: DRSC
blink
uint32
•
0
: The disk's locator LED is not illuminated.
•
1
: The disk's locator LED is illuminated.
speed
uint32
Not used.
lun
uint32
Not used.
smart
string
•
Disabled
: SMART is disabled for this disk.
•
Enabled
: SMART is enabled for this disk.
smart-numeric
string
Numeric equivalents for
smart
values.
•
0: Disabled
•
1: Enabled
dual-port
uint32
•
0
: Single-ported disk.
•
1
: Dual-ported disk.
error
uint32
Not used.
fc-p1-channel
uint32
Port 1 channel ID.
fc-p1-device-id
uint32
Port 1 device ID.
fc-p1-node-wwn
string
Port 1 WWNN.
fc-p1-port-wwn
string
Port 1 WWPN.
fc-p1-unit-
number
uint32
Port 1 unit number.
fc-p2-channel
uint32
Port 2 channel number.
fc-p2-device-id
uint32
Port 2 device ID.
fc-p2-node-wwn
string
Port 2 WWNN.
fc-p2-port-wwn
string
Port 2 WWPN.
fc-p2-unit-
number
uint32
Port 2 unit number.
drive-down-code
uint8
Numeric code indicating why the disk is down.
Table 26
drives properties (continued)
Name
Type
Description
Содержание P2000 G3
Страница 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Страница 14: ...14 About this guide ...
Страница 30: ...30 Categorical list of commands ...
Страница 96: ...96 Alphabetical list of commands exit Description Log off and exit the CLI session Syntax exit ...
Страница 159: ...HP P2000 G3 MSA System CLI Reference Guide 159 See also set host parameters show iscsi parameters ...
Страница 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Страница 217: ...HP P2000 G3 MSA System CLI Reference Guide 217 Basetypes drives enclosure list status See also show vdisks ...
Страница 223: ...HP P2000 G3 MSA System CLI Reference Guide 223 Basetypes email parameters status See also set email parameters ...
Страница 230: ...230 Alphabetical list of commands See also clear events set snmp parameters show snmp parameters ...
Страница 288: ...288 Alphabetical list of commands Basetypes snapshots status See also show master volumes show snap pools ...
Страница 292: ...292 Alphabetical list of commands Basetypes system unhealthy component status See also set system ...
Страница 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Страница 338: ...338 Alphabetical list of commands Basetypes remote links See also show remote systems verify remote link ...
Страница 340: ...340 Alphabetical list of commands Basetypes remote links See also show remote systems verify links ...
Страница 424: ...424 XML API basetype properties PROPERTY name utility priority numeric type string 0 PROPERTY OBJECT ...
Страница 469: ...HP P2000 G3 MSA System CLI Reference Guide 469 PROPERTY name status type string OK PROPERTY OBJECT ...
Страница 494: ...494 XML API basetype properties PROPERTY name sample time numeric type string 1329397200 PROPERTY OBJECT ...
Страница 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Страница 510: ...510 XML API basetype properties PROPERTY name reserve type numeric type string 0 PROPERTY OBJECT ...
Страница 524: ...524 Glossary ...
Страница 532: ...532 Index ...