186 Alphabetical list of commands
set user
Description
Changes user preferences for the session or permanently. The system requires at least one CLI user
with the
manage
role to exist.
NOTE:
User changes take effect when the user next logs in.
Syntax
set user
[authentication-type MD5|SHA|none]
[base 2|10]
[interfaces
interfaces
]
[level monitor|manage]
[locale English|en|Spanish|es|French|fr|German|de|Italian|it|Japanese|ja
|Korean|ko|Dutch|nl|Chinese-simplified|zh-s|Chinese-traditional|zh-t]
[password
password
]
[precision
#
]
[privacy-password
encryption-password
]
[privacy-type DES|AES|none]
[session-preferences]
[storage-size-base 2|10]
[storage-size-precision
#
]
[storage-size-units auto|MB|GB|TB]
[temperature-scale celsius|c|fahrenheit|f]
[timeout
#
]
[trap-host
IP-address
]
[type novice|standard|advanced|diagnostic]
[units auto|MB|GB|TB]
name
Parameters
authentication-type MD5|SHA|none
Optional. For an SNMPv3 user, this specifies whether to use a security authentication protocol. This
parameter requires the password parameter and, for the
snmptarget
interface, the
trap-host
parameter.
•
MD5
: MD5 authentication. This is the default.
•
SHA
: SHA (Secure Hash Algorithm) authentication.
•
none
: No authentication.
base 2|10
Optional. Sets the base for entry and display of storage-space sizes:
•
2
: Sizes are shown as powers of 2, using 1024 as a divisor for each magnitude.
•
10
: Sizes are shown as powers of 10, using 1000 as a divisor for each magnitude. This is the
default.
Operating systems usually show volume size in base 2. Disk drives usually show size in base 10.
Memory (RAM and ROM) size is always shown in base 2.
Содержание P2000 G3
Страница 1: ...HP P2000 G3 MSA System CLI Reference Guide Part number 500912 009 First edition February 2014 ...
Страница 14: ...14 About this guide ...
Страница 30: ...30 Categorical list of commands ...
Страница 96: ...96 Alphabetical list of commands exit Description Log off and exit the CLI session Syntax exit ...
Страница 159: ...HP P2000 G3 MSA System CLI Reference Guide 159 See also set host parameters show iscsi parameters ...
Страница 199: ...HP P2000 G3 MSA System CLI Reference Guide 199 See also set cache parameters show volumes ...
Страница 217: ...HP P2000 G3 MSA System CLI Reference Guide 217 Basetypes drives enclosure list status See also show vdisks ...
Страница 223: ...HP P2000 G3 MSA System CLI Reference Guide 223 Basetypes email parameters status See also set email parameters ...
Страница 230: ...230 Alphabetical list of commands See also clear events set snmp parameters show snmp parameters ...
Страница 288: ...288 Alphabetical list of commands Basetypes snapshots status See also show master volumes show snap pools ...
Страница 292: ...292 Alphabetical list of commands Basetypes system unhealthy component status See also set system ...
Страница 294: ...294 Alphabetical list of commands See also set volume set vdisk ...
Страница 338: ...338 Alphabetical list of commands Basetypes remote links See also show remote systems verify remote link ...
Страница 340: ...340 Alphabetical list of commands Basetypes remote links See also show remote systems verify links ...
Страница 424: ...424 XML API basetype properties PROPERTY name utility priority numeric type string 0 PROPERTY OBJECT ...
Страница 469: ...HP P2000 G3 MSA System CLI Reference Guide 469 PROPERTY name status type string OK PROPERTY OBJECT ...
Страница 494: ...494 XML API basetype properties PROPERTY name sample time numeric type string 1329397200 PROPERTY OBJECT ...
Страница 498: ...498 XML API basetype properties PROPERTY name mrc version type uint8 0 PROPERTY OBJECT ...
Страница 510: ...510 XML API basetype properties PROPERTY name reserve type numeric type string 0 PROPERTY OBJECT ...
Страница 524: ...524 Glossary ...
Страница 532: ...532 Index ...