Wuxi Betteri Electronic Technology CO.,LTD

3 pin AC Connector For PV System

Instruction

 

Book

(

BC01

Cable to Cable

)

Warning

Do

 

Not

 

Connect

 

Or

 

Disconnect

 

Under

 

Load!

Summary of Contents for BC01

Page 1: ... 2015 9 Version 4th Wuxi Betteri Electronic Technology CO LTD 3 pin AC Connector For PV System Instruction Book BC01 Cable to Cable Warning Do Not Connect Or Disconnect Under Load ...

Page 2: ...cable to cable 1 Contents 1 Application Structure 2 2 Product Outline Size 3 3 Type of the connector 4 4 Main Technical Features 5 5 Safety Precautions 6 6 For Assembly 6 7 Instruction of Operation 11 8 Maintenance 12 9 Statement 13 ...

Page 3: ...e 1 1 The connectors are specialized for the connection of inverter equipment in terrestrial PV systems 1 2 The connection of pin and wire is screw type which is easy for field installation and the connection of the male and the female connector is snap fit type 1 3 Easy operation reliable performance on mechanical and electrical properties The connector may be used in other areas and industries w...

Page 4: ...BC01 Instruction Book Of BC01 cable to cable 3 2 Product Outline Size 2 1 Outline of male cable connector 2 PE 2 2 Outline of female cable connector 2 PE ...

Page 5: ...cable to cable 4 3 Type 3 1 BC01 CC Connector type BC01 CC 3 2 Male cable connector type 3 3 Female cable connector type TUV CSA 250V 25A BC01 3M22 15 CSA 350V 25A BC01 3M32 15 TUV CSA 250V 25A BC01 3F22 15 CSA 350V 25A BC01 3F32 15 ...

Page 6: ...r 2P PE Insulation resistance 100MΩ Rated voltage TUV 250V AC CSA 350V AC Rated impulse withstand voltage 4000V AC Rated current 25A 4mm Degree of protection IP68 1 5m 24h Material of pin Copper alloy silver plated Insertion and withdraw force unlocked 10 50N Contact resistance 1mΩ Applicable wire gauge 2 5 4 0mm2 Pollution degree 2 Outer cable diameter 10 13mm Enclosure flame class UL94 V0 Standa...

Page 7: ... using it immediately and contact sales or our company directly 5 3 Please ensure the inverter system is not under working conditions firstly when installing connectors The human body cannot simultaneously contact the connector s positive and negative pole in order to avoid electric shock accidents 5 4 The operator who installs or maintains the product shall be trained and have related electrical ...

Page 8: ... wrench wider than 3cm and 30 solid wrench 6 2 Strip cables Only multiple strands of copper wire can be used Please cut and strip the wire according to the requirements and the ground wire needs to be 5mm longer than live and naught wire and the applicable stripping length is 7 8mm strip length Ground wire ...

Page 9: ...p the wire Inserting the stripped wires correctly into the corresponding pin holes according to the identification and then tightening all screws firmly Screw twisting torque 0 4 0 1N m after it giving a reverse pull force lightly about 10N by manual to test crimping result Please pay attention to avoiding damage of pins and pin holder After crimping The tensile strength shall meet the requirement...

Page 10: ...h the male or female cable body into housing body correctly according to the position of the clamping groove and will hear a crisp click sound in place Conductor cross section area mm2 Required tensile strength N 2 5 50 4 0 60 click Male cable body Housing body Male cable body Cable Cable Female cable body ...

Page 11: ...cable to cable 10 6 3 4 Push the sealing body and sealing craw into the housing body and then tighten the end locker torque 4 0 0 5N m click Housing body Female cable body Wire Sealing claw Housing Body Wire Sealing Cable End Locker ...

Page 12: ...ing 7 2 When mating connectors align mate locker on the male connector with grooves on the female connector and insert gradually Connected in place there will be a sound of click 7 3 If the connectors are separated choose a corresponding flat screwdriver to push mate locker step slightly out of position and then give a force along the axial direction until separation Click mate locker ...

Page 13: ...orward slightly and when the tongue comes off a little use the same method to the tongue on other side Give a force along the axial direction until separation 8 Maintenance The user should do maintenance work according to the different operating environments and frequencies If discovering any damage of connector systems please stop using and change it immediately Please do not separate and mate th...

Page 14: ...oading if you need more copies All technical data is for reference only when using the product Any commercial purpose application is forbidden Wuxi Betteri Electronic technology Co Ltd owns the copyright and the right of final interpretation Wuxi Betteri Electronic technology Co Ltd is entitled to conduct any further modification to the print error technical improvement and innovation without prio...

Page 15: ... Electronic Technology CO LTD Tel 0086 0510 88771606 Fax 0086 0510 88770676 Zip code 214037 Add 11 5 1 Wuxi Optoelectronic Materials Science Technology Park 5 1 11 JinShan Rd Branch 4 Wuxi China Your better choice ...