Table 2-1 Hardware Specifications
(continued)
HP Integrity rx2660
Component
One DVD-R or DVD+RW.
Optical device
The Data Center server has one 900 watt (@120 VAC) or 1000 watt (@240 VAC) power supply,
1+1 redundancy with second power supply.
The Office Friendly configuration includes two power supplies.
Power supply
Dimensions and Weight
Table 2-2
lists the dimensions and weight of the HP Integrity rx2660 Data Center server and the
rx2660 Office Friendly server for a rack- or pedestal-mounted configuration.
Table 2-2 Rack- or Pedestal-Mounted Server Dimensions
Value
Dimensions and Weight
Data Center Server Dimensions
• 67.3 cm (26.5 in)
• Depth
• 48.3 cm (19 in)
• Width
• 8.6 cm (3.4 in)
• Height
Minimum configuration – 21 kg (46 lb)
Maximum configuration – 28 kg (61 lb)
Data Center Server Weight
2U
Rack unit
Office Friendly Server Dimensions
• 69.0 cm (27.18 in)
• Depth
• 27.6 cm (10.88 in) w/feet
12.7 cm (5 in) w/o feet
• Width
• 50.8 cm (20 in)
• Height
Minimum configuration – 30 kg (66 lb)
Maximum configuration – 37 kg (81 lb)
Office Friendly Server Weight
Grounding
The site building shall provide a safety ground/protective earth for each ac service entrance to
all cabinets.
Install a PE (protective earthing) conductor that is identical in size, insulation material, and
thickness to the branch-circuit supply conductors. The PE conductor must be green with yellow
stripes. The earthing conductor is to be connected from the unit to the building installation earth
or, if supplied by a separately derived system, at the supply transformer or motor-generator set
grounding point.
Electrical Specifications
This section provides electrical specifications for the server.
System Power Specifications
Available power (output) is the maximum dc power that the power supply can supply to the
system.
Maximum input power is what the power supply requires from the ac line to deliver that
maximum dc output (given worst case efficiency and maximum loading).
Dimensions and Weight