5.
Pull the PCIe expansion board straight up and out of the server (2).
Figure 6-43 Removing the PCIe Expansion Board
Replacing the Smart Array P400 Controller Board
To replace the Smart Array P400 controller board, follow these steps:
1.
Insert the SAS core I/O Smart Array P400 controller board into the dedicated slot:
a.
Align the card connector with the slot on the system board.
b.
Apply firm, even pressure to both sides of the card until it fully seats into the slot.
c.
Close the SAS core I/O Smart Array P400 controller board lock. See
Figure 6-41
.
CAUTION:
When reconnecting the SAS cables, note the labeling on the channel cables.
Match each cable with the appropriate socket on the SAS core I/O board. If the cables are
mismatched, the server will not reboot. Both cables and sockets are clearly marked with the
correct channels.
2.
Reconnect the internal SAS cables to the SAS core I/O Smart Array P400 controller board.
3.
To install the battery onto the airflow guide, follow these steps:
a.
Insert the posts on the battery into the slots on the airflow guide.
b.
Slide the battery until it clicks into place (1). See
Figure 6-44
.
194
Removing and Replacing Server Components