Model 3585A
Performance Tests
i. Press the 1 MO input impedance key on the 3585A.
j . Again check the amplitude of the scope waveform . It should be less than 0.07 V p-p .
This will confirm that the Return Loss of the Terminated input is greater than 1 4 dB .
k . Connect the equipment as shown in Figure 4-2. 750 Return Loss Test .
1.
Press the 750 input impedance key on the 3585A.
m. Repeat Steps e thru i for the values in parenthesis .
n . Change the synthesizer frequency to 1 5 MHz.
o . Set the 3585A controls for MANUAL SWEEP 1 5 MHz .
p . Repeat Steps c thru m .
q . This completes the Return Loss Tests . Disconnect the test equipment .
h p 3585A
SPECTRUM ANALYZER
1iI�
j jjjj
Ej
0
....J ....J ....J
...J ....J
-'�-.l -.l -.l-.l-.l-.l -'-'-'
-'�-.l -.l -.l-.l-.l-.l
-' : : -'-'-' -'�-.l -.l-.l-.l-.l -'-;-;
m
e o e o 0 0 0
0
• •
SYNTHES I ZER
15 OHM OUTPUT OR
50 OHM TO 15 OHM
M I N I _ LOSS PAD
OSC I LLOSCOPE
LOAD PORT
SHORTED
" _ �" ,, _
D
15 OHM CABLE
FEEDTHRU
TERM I NAT I ON
Figure 4·2. 7 50 Return Loss Test (Operational Verification)
4-1 5