4· 1 . INTRODUCTION
SECTION IV
PERFORMANCE TESTS
This section contains the procedures for the performance tests which verify that the 3585A
will meet its published specifications as listed in Table 1 - 1 . Access to the interior of the in
strument is not needed to perform any of the tests. Two different types of tests are included
in this section: Operation Verification Tests and Semi-Automatic Performance Tests. The
Operational Verification Tests will give you a good indication that the 3585A is working as
specified; however, they do not verify that the 3585A meets all its specifications. The Semi
Automatic Performance Tests will verify that the 3585A meets all of its published specifica
tions.
4·2. CALIBRATION CYCLE
The 3585A requires verification of its specified performance every 12 months. The Semi
Automatic Performance Tests should be used when verifying performance specifications.
The Operational Verification Tests can be used as part of an incoming inspection or after a
repair is made to the instrument. The filter screen on the fan should be cleaned each time the
instruments performance is tested or verified.
4·3. PERFORMANCE TEST RECORD
An Operational Verification Test Card is provided at the end of this section for your conve
nience to record the performance of the 3585A during the Operational Verification Tests.
This card can be removed from the manual and used as a permanent record of the incoming
inspection or of a routine performance verification. The Operational Verification Test Card
may be reproduced without the written permission of Hewlett-Packard. When performing
Semi-Automatic Performance Tests, it is not necessary to complete the test card because the
semi-automatic tests will generate a printout for you with all test results. The printout will be
very similar to that of the Operational Verification Test Card; however, in some cases the
printout generated by the Semi-Automatic Performance Tests will actually plot measure
ment data results .
4·4. RECOMMENDED TEST EQUIPMENT
The equipment that is recommended for testing the 3585A is listed in Table 4-1 . If the
recommended model is not available, use a substitute that meets the "Required
Characteristics" given in the table. When using the Semi-Automatic Performance Tests, see
Paragraph 4-33 for details concerning program compatible instruments required by the
semi-automatic tests .
4-1