17.5 Refrigerant
The air conditioning system is operated
with refrigerant (filling capacity 1,200 g
with emptied system) R134a (tetrafluoro
ethane). This substance does not contain
any chlorine atoms and is thus harmless
for the ozone in the atmosphere.
However, the refrigerant must not simply
be released into the atmosphere, but must
be collected in a recycling system.
Connecting lines must therefore not be
disconnected. Have maintenance and
repair work on the air conditioning system
solely carried out by your HORSCH sales
partner using appropriate disposal and
recycling facilities.
17.6 Pressure switch
With the highest, still pleasant fan speed
stage adjust the cooling power of the air
conditioning system to a medium value.
Do not allow the air conditioning system
to run with lowest fan speed and highest
cooling power.
The air conditioning system is equipped with a pressure
switch (1), which switches the system off in case of
overpressure or vacuum (on collector/drier (2) in travel
direction left on roll over protection structure (ROPS)).
182