Pay attention to the danger notes issued
by the manufacturer, which are attached
to the battery in form of a sticker!
16.5 Cleaning the battery
• Wash the battery, if required.
• Remove possible oxidation from the terminal clamps
with a brush.
• Apply some grease to battery terminals and terminal
clamps.
• Keep the ventilation bores in the plugs open.
16.6 Installing batteries and
connecting with correct polarity
Always connect the batteries with correct
polarity.
Connect the plus cable (from the starter)
to the plus poles, the minus cable (from
ground) to the minus poles.
Failure to comply with the correct
polarity between battery and three-phase
alternator causes severe damage.
16.7 Three-phase alternators
When working in the electric system
disconnect the plus cable from the
batteries, to avoid damage.
Protect the cable contacts of the plus
cables against accidental contact with
the battery contacts.
Have three-phase alternators check in a professional
workshop once every year.
Pay attention to the warning lamps on
the switch console in the cabin.
In case of a defective three-phase generator you will be
warned by the control lamps (1), 24V and (2), 12V on the
console inside the cabin.
Should the control lamp (1) light up, it indicates a defect
in the main generator (which is located in travel direction
on the right hand side).
If the control lamp (2) lights up, the additional generator
(in travel direction left) needs to be checked.
1
2
2
1
175
Содержание 80910205
Страница 2: ......
Страница 8: ...8...
Страница 39: ...04002623 04003745 04003747 04002625 04002626 39...
Страница 44: ...44...
Страница 82: ...82...
Страница 164: ...14 11 Manual transmission coolant circuit 1 Transmission lubrication pump 2 Filter 3 Transmission oil cooler 1 3 2 164...
Страница 173: ...11 7 8 9 10 173...
Страница 188: ...188...
Страница 216: ...216...
Страница 217: ......