Using the Security System (cont’d)
41
Fire and Carbon Monoxide Alarm Operation
Your fire alarm system and carbon monoxide detector (if installed) is on 24 hours a day, providing continuous protection.
In the event of an emergency, the installed smoke, heat, carbon monoxide detectors automatically send signals to your
Control/Communicator, triggering a loud interrupted sound from the keypad. An interrupted sound is also produced by
optional exterior sounders. EVACUATE ALL OCCUPANTS FROM THE PREMISES IMMEDIATELY. Notify your Central
Station/Security Company immediately and wait for further instructions.
CO annunciation may not be used for agency compliant installations due to no investigation has been completed.
In Case of Fire Alarm
1.
A
FIRE
message appears at your keypad and remains on until you silence the alarm.
2.
Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest keypad
and manually initiate an alarm by pressing the panic key assigned as
FIRE
emergency (if programmed by the
installer) and hold down for at least 2 seconds.
3.
Evacuate all occupants from the premises.
4.
If flames and/or smoke are present, leave the premises and notify your local Fire Department immediately.
Silencing and Clearing a Fire/Carbon Monoxide Alarm
1.
Silence, acknowledge, and clear the alarm by:
a.
For Residential Systems:
Press “Touch here to Silence” on the display to silence the alarm.
For Commercial Systems:
Enter your code. This silences and acknowledges the alarm and disarming of the
system (if armed).
b.
For Residential Systems:
Press
CLEAR
followed by your code. This acknowledges the alarm and the
disarming of the system (if armed).
For Commercial Systems:
Press
CLEAR
followed by your code.
The system attempts to clear the alarm from
memory. If NOT successful (i.e., smoke in the detector) the Security screen is displayed and
Display
Faults
displays a “Not Ready Fault.”
c.
Press
DISPLAY FAULTS
on the Arming screen. The faulted fire/carbon monoxide zone is displayed.
d.
Press
CLEAR
and then enter your code. This clears the Fire Alarm/CO Alarm from the system.
2.
If the keypad does not indicate a
READY
condition after the second sequence, press the
DISPLAY FAULTS
key on
the Arming screen to display the zone(s) that are faulted. Be sure to check that smoke detectors/carbon monoxide
detectors are not responding to smoke, heat, or gas producing objects in their vicinity. In this case, eliminate the
source of heat, smoke or leak.
3.
If this does not remedy the problem, there may still be smoke/gas in the detector. Clear it by fanning the detector for
about 30 seconds.
4.
When the problem has been corrected, clear the display by entering
DISPLAY FAULTS
on the Arming screen,
selecting the fire or carbon monoxide zone, pressing
CLEAR
and then entering your user code.
Note:
Contact your Central Station/Security Company for servicing if you have further problems with your system.