• Communication Format: The data length is fixed at eight bits. No parity bit or multiprocessor
bit can be added.
• Clock: An internal clock generated by the on-chip baud rate generator or an external clock input
from the SCK pin can be selected by clearing or setting the CKE1 bit in the serial control register
(SCR). See table 8-5.
When the SCI operates on an internal clock, it outputs the clock signal at the SCK pin. Eight clock
pulses are output per transmitted or received character. When the SCI is not transmitting or
receiving, the clock signal remains at the high level.
(2) Transmitting and Receiving Data
• SCI Initialization: The SCI must be initialized in the same way as in asynchronous mode. See
figure 8-4. When switching from asynchronous mode to clocked synchronous mode, check that the
ORER, FER, and PER bits are cleared to “0.” Transmitting and receiving cannot begin if ORER,
FER, or PER is set to “1.”
198