3.3.2 How to Calculate Where the Execution Starts
Table 3-2 shows how to calculate the Effective Address (EA: Effective Address) for each
addressing mode.
In the operation instruction, 1) register direct, as well as 6) immediate (for each instruction,
ADD.B, ADDX, SUBX, CMP.B, AND, OR, XOR) are used.
In the move instruction, 7) program counter relative and 8) all addressing mode to delete the
memory indirect can be used.
In the bit manipulation instruction for the operand specifications, 1) register direct, 2) register
indirect, as well as 5) absolute address (8 bit) can be used. Furthermore, to specify the bit number
within the operand, 1) register direct (for each instruction, BSET, BCLR, BNOT, BTST) as well as
6) immediate (3 bit) can be used independently.
29
Содержание H8/326 Series
Страница 67: ...58 ...
Страница 121: ...112 ...
Страница 274: ... 3 Clock Settling Timing Ø VCC RES STBY tOSC1 tOSC1 Figure 14 8 Clock Setting Timing 265 ...
Страница 279: ...270 ...