9.2 Register Descriptions
9.2.1 A/D Data Registers (ADDR)—H'FFE0 to H'FFE6
Bit
7
6
5
4
3
2
1
0
ADDRn
Initial value
0
0
0
0
0
0
0
0
Read/Write
R
R
R
R
R
R
R
R
(n = A to D)
The four A/D data registers (ADDRA to ADDRD) are 8-bit read-only registers that store the results
of A/D conversion. Each data register is assigned to two analog input channels as indicated in
table 9-3.
The A/D data registers are always readable by the CPU.
The A/D data registers are initialized to H'00 at a reset and in the standby modes.
Table 9-3. Assignment of Data Registers to Analog Input Channels
Analog input channel
Group 0
Group 1
A/D data register
AN
0
AN
4
ADDRA
AN
1
AN
5
ADDRB
AN
2
AN
6
ADDRC
AN
3
AN
7
ADDRD
9.2.2 A/D Control/Status Register (ADCSR)—H'FFE8
Bit
7
6
5
4
3
2
1
0
ADF
ADIE
ADST
SCAN
CKS
CH2
CH1
CH0
Initial value
0
0
0
0
0
0
0
0
Read/Write
R/(W)*
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Note: * Software can write a “0” in bit 7 to clear the flag, but cannot write a “1” in this bit.
The A/D control/status register (ADCSR) is an 8-bit readable/writable register that controls the
operation of the A/D converter module.