174
Configuring the Numerical Calculation Settings
Setting
Description
Sample screen
Arithmetic
operations
Calculation number 1
,
Calculation number 2
(No. 1 to No. 15)
Allows you to specify two
numerical calculation numbers
to use for calculations.
Target channel
Allows you to specify a target
channel that has a numerical
calculation number to use for
calculations.
Operator
(
+
,
−
,
×
,
÷
)
Allows you to choose among
the four basic arithmetic
operations.
CAN statistics
Target channel
(C1 to C4)
Allows you to specify a CAN
channel used as the calculation
target.
ID
(0 to 1FFFFFFF)
Allows you to specify a CAN
channels as calculation targets
in hexadecimal notation.
• With the
[Period]
,
[Frequency]
,
[Rise time]
, and
[Fall time]
calculations, the instrument may not
be able to perform calculations depending on the condition of waveform data.
• With the
[Period]
and
[Frequency]
calculation, correct measurement results may not be
obtained if the filter setting is close to half the period (an integer multiple of an actual period may
be calculated).
• When the scaling is enabled, the instrument scales waveform data before calculation. Units for
parameter values are those set in the scaling function.
• If a waveform across a calculation target channel exceeds the measurable range (overrange
waveform), the instrument substitutes the upper or lower measurement limit for values that
exceed the measurable range before calculation.
See “3.2 Converting Input Values (Scaling Function)” (p. 54).
Settings: Calculations for which
[Stat.]
can be set
Period, frequency, rise time, fall time, pulse width, duty ratio, time lag, phase contrast, +Width, −Width, and
burst width
Top
Performs calculations within the calculation range in the initial condition.
Average
Calculates the average value of calculation results for data within the calculation
range.
Max
Calculates the maximum value of calculation results for data within the calculation
range.
Min
Calculates the minimum value of calculation results for data within the calculation
range.
Times
Calculates the value when the number of times a waveform crosses the level reaches
the specified number for data within the calculation range.
HIOKI MR6000A966-03
Содержание Memory HiCorder MR6000
Страница 2: ...HIOKI MR6000A966 03...
Страница 56: ...50 Displaying Measured Values HIOKI MR6000A966 03...
Страница 152: ...146 Triggering the Instrument Using CAN Signals CAN Trigger HIOKI MR6000A966 03...
Страница 194: ...188 Numerical Calculation Types and Descriptions HIOKI MR6000A966 03...
Страница 266: ...260 Configuring the Display Settings HIOKI MR6000A966 03...
Страница 391: ...HIOKI MR6000A966 03...
Страница 392: ...HIOKI MR6000A966 03...