Appendix 1 Error Messages
A
3
Appe
ndix
38
Invalid operation (measuring).
The operation is not available while mea-
suring. Try again after measuring finishes.
39
Invalid operation (printing).
The operation is not available while print-
ing. Try again after printing finishes.
41
Recording length is set to Continuous.
When the Recording Length (Shot) is set
to Continuous (Cont), real-time printing is
not available with fast timebase settings
"12.2 Print Methods and
Print Items" (p. 315)
42
There is no calculation result.
There is no calculation result. Print results
after performing calculation.
Analysis and
Communication
Supplement
43
Over event mark count(1000).
Up to 1,000 event marks are supported.
44
No event mark.
An event mark has not been set.
45
Out of range.
Check the valid setting range, and reset.
46
Invalid operation(accessing file).
The operation is not available during file
processing. Try again when file process-
ing finishes.
50
Roll Mode is not available.
The Roll Mode cannot be used when
Overlay is enabled.
"4.3.1 Displaying Wave-
forms During Recording
(Roll Mode)" (p. 102)
54
Function not available. (Averaging,
Overlay,Wave Calculation)
Averaging, Overlay and Waveform calcu-
lation functions are prohibited when the
Roll Mode is set to [On] or [Auto].
"4.3.1 Displaying Wave-
forms During Recording
(Roll Mode)" (p. 102)
56
Real-time printing is not available.
Recording Length is set to [Cont]. Real-
time printing is not available when the time
base of the Recorder function is 10 to 200
ms/div.
"Setting Continuous Re-
cording (Cont)"(p. 101)
58
Function not available.(Averaging)
The Averaging function is not available
when Memory Division is enabled.
59
Function not available. (Averaging,
Wave Calculation)
When Memory Division is enabled, Aver-
aging and Waveform Calculation func-
tions are not available. If enabled, these
functions are turned off.
60
No waveform data.
Acquire waveform data.
61
Function not available. (Roll Mode, Av-
eraging, Memory Division)
When Waveform Calculation is enabled,
Roll Mode, Averaging and Memory Divi-
sion functions are not available. If en-
abled, these functions are turned off.
63
Function not available.(Trigger Priority)
Trigger priority cannot be set when Aver-
aging is enabled.
64
Up to eight clamps can be used.
Up to eight channels can be used simulta-
neously when clamps are connected to
the Model 8940 with Model 9318 or 9319
Conversion Cables. Do not exceed this
clamp limitation. When using the Model
9325 connected to the 9322, up to eight
channels can be used for clamps and the
Model 9322 together.
Input Module Guide
:
Displayed Warnings
Msg
No.
Message
Remedial Action
Reference
Содержание 8860-50
Страница 2: ......
Страница 12: ...Contents x...
Страница 18: ...Reading this Manual 6...
Страница 24: ...1 3 Interconnection and Block Diagrams 12...
Страница 180: ...6 12 Making Trigger Settings on the Waveform Screen 168...
Страница 246: ...8 15 Inserting and Searching for Event Marks on a Waveform 234...
Страница 354: ...12 7 Print Examples 342 Print Example 4 Row Printing 1 4 steps Settings data Each step is 25 div...
Страница 356: ...12 7 Print Examples 344 A B Waveform_________________________________________________...
Страница 360: ...12 7 Print Examples 348 Event ________________________________________________________ Event mark...
Страница 406: ...14 2 External I O 394...
Страница 489: ......
Страница 490: ......