![Hewlett Packard Enterprise StoreEver 8096 Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/hewlett-packard-enterprise/storeever-8096/storeever-8096_users-and-service-manual_2128096060.webp)
Figure 25: System Status pane
The System Status pane displays the following:
• Updated — the day, date, and time of the most recent status view. This time stamp comes from your
computer and might be different from the library Time at the bottom of the pane. To refresh the system
status, click your browser reload button.
• Library Name — the name of the library, which was set in the Configuration > System screen.
• Status of the library and tape drives
The green
Status Ok
icon indicates that the device is fully operational and that no user
intervention is required.
The blue exclamation point
Status Warning
icon indicates that user attention is necessary, but
that the device can still perform most operations.
The red X
Status Error
icon indicates that user intervention is required and that the device is
not capable of performing some operations.
• Slots (Free/Total) —
Free
is the number of empty storage slots.
Total
is the number of storage slots
available to the host software, which does
NOT
include reserved slots.
• Mailslot — shows whether the mailslot is open, closed, or disabled.
• Library Time — the date and time from the library, which can be set from the OCP or RMI. The Library
Time is updated when the system status is refreshed. The time of the most recent refresh is the Updated
time at the top of the pane. If you call the service organization to request a temporary administrator
password, refresh the system status with your browser reload button and then give the service engineer
this Library Time.
• Power Supply Status (MSL4048, MSL8048 and MSL8096)
◦ MSL4048— Online — The power supply is installed.
◦ MSL8048 and MSL8096 — Good — The power supply is functioning correctly.
◦ MSL8048 and MSL8096 — Functional, fan failure — the power supply is supplying power to the library,
but the fan has failed so the power supply could fail soon. Replace the power supply.
60