Event code
Description
Details and Solution
48
SCSI: tape drive not supported by this library The tape drive is not supported by the
firmware in this device. Upgrade the device
firmware to the most up-to-date version.
Verify that the drive has an HPE MSL-G3 or
1/8 G2 firmware revision. If firmware is not
the correct type, the wrong tape drive has
been installed. Use only Hewlett Packard
Enterprise-approved support to insure that
the correct tape drives are used.
49
SCSI: incompatible magazine, magazine not
accessible
Verify that a supported magazine for that
slot is inserted. If the magazine is in the
lower left position, verify that the type of
magazine is consistent with the mailslot
configuration.
4A
Source not ready
• Retry the operation.
• Check the status of extended libraries.
4B
Destination not ready
• Retry the operation.
• Check the status of extended libraries.
4C
Reservation failed
The application software made an illegal
request.
4D
Library controller busy
Retry the operation.
4E
Invalid robotic request
4F
Robotic not initialized
50
Cartridge location in a different partition;
move across partition boundaries was
initiated.
The library will not move a cartridge from
one logical library to another logical library.
To move a cartridge from one logical library
to another:
1.
Move the cartridge to the mailslot.
2.
Remove the cartridge from the mailslot.
3.
Close the mailslot.
4.
Replace the cartridge in the mailslot.
5.
Move the cartridge to a slot in the new
logical library.
Table Continued