![Hewlett Packard Enterprise StoreEver 8096 Скачать руководство пользователя страница 180](http://html1.mh-extra.com/html/hewlett-packard-enterprise/storeever-8096/storeever-8096_users-and-service-manual_2128096180.webp)
Error code
Description
Details and solution
B8
Library Extender missing.
See Sub-codes for error B8 for details.
• If this is a new installation, verify that the
Extender is installed properly and that
both libraries are powered on.
• Update the firmware to the latest
version.
• Power cycle both libraries.
B9
Communication error on the I²C bus
between the master library and the
Extender.
See Sub-codes for error B9 for details.
• If this is a new installation, verify that the
Extender is installed properly and that
both libraries are powered on.
• Update the firmware to the latest
version.
• Power cycle both libraries.
BA
Communication error on the serial
connection between the master and lower
libraries.
The master library cannot communicate
with the lower library.
• If this is a new installation, verify that the
Extender is installed properly and that
both libraries are powered on.
• Update the firmware to the latest
version.
• Power cycle both libraries.
BB
Stack link not established due to
communication issues between the master
and lower libraries.
The master library has some
communication with the lower library, but
not enough to function.
• If this is a new installation, verify that the
Extender is installed properly and that
both libraries are powered on.
• Update the firmware to the latest
version.
• Power cycle both libraries.
Table Continued
180
Troubleshooting information and procedures