Manual ERS-BIC 160 kW V2.1
97
B . B .
Co nt r o l S c he m a t i c s
Main controller: PI-controller
Parameters P and I separately adjustable for each control mode (CV, CC, CP)
Subordinate current controller: PI controller Parameter P and I adjustable
Ramp: separately adjustable for each control mode (CV, CC, CP)
B . C .
Co nt r o l P a r a m e t e r V a l ue Ra ng e s
B . C . A .
V o l t a g e Co nt r o l
Voltage Control
Setting Range
Typical Value
P-ratio
0.0001 … 6500
0.1 … 6.5
I-ratio
0.0001 … 6500
0.01 … 1.0
Ramp
0 … 1000 V/ms y 0 … 1000 ms
0,1 … 1000
B . C . B .
C ur r e nt Co nt r o l
Current Control
Setting Range
Typical Value
P-ratio
0.0001 … 6500
0.1….…2.0
I-ratio
0.0001 … 6500
0.01……1.0
Ramp
0 … 350 A/ms , 0 … 10000 ms
0,1.……600
B . C . C .
P o w e r Co nt r o l
Power Control
Setting Range
Typical Value
P-ratio
0.0001 … 6500
0.1 … 1.0
I-ratio
0.0001 … 6500
0.01 … 0.5
Ramp
0 … 8.00 kW/ms, 0 … 10000 ms
0,1 … 100
Current control (subordinate)
Setting Range
Typical Value
P-ratio
0.0001 … 6500
0.12 … 0.3
I-ratio
0.0001 … 6500
0