Manual ERS-BIC 160 kW V2.1
95
CH_READ_WARN_ACK
0x1D1 => Channel 1
0x1D2 => Channel 2
8 Byte
DSP
Remote
Byte
Bits
Values
Max./Min.
Name
Description
0
0-5
0..63
0..50
CH_WARN_NO
Error memory number
0
6-7
0..65355
0..9999
CH_WARN_CODE
Channel warning code
2-3
22-31
0..1023
0..999
TIMESTAMP 0
Timestamp in ms
4-7
32-63
0..FFFFFFFFh
0..4294967295
TIMESTAMP 1
Timestamp in s since 1970-01-01
A . S .
S y s t e m i n f o r m a t i o n
Query of specific system information
ID-Name
Message ID
Length
Sender
Receiver
CH_QUERY_SYSTEM_INFO
0x391 => Channel 1
0x392 => Channel 2
2 Byte
Remote
DSP
-
Byte Bits
Values
Min./Max
Name
Description
0-1
0-15
0..65535
0 - 65533
Index
Index of query (see below)
The following queries return the information in ASCII
Index == 0x000 SW-Version DSP1
Index == 0x001 SW-Version DSP2
Index == 0x002 SW-Version FPGA
Index == 0x010 serial number
Index == 0x020 date of last calibration (yyyymmdd)
Index == 0x040 designation of the device
ID-Name
Message ID
Data Length
Sender
Receiver
CH_SYSTEM_INFO_RESP
0x171 => Channel 1
0x172 => Channel 2
8 Byte
DSP
Remote
Byte
Bits
Values
Name
Description
0 - 7
0-63
--
Spec. value
ASCII Code of the message
The following queries return the answer as a numerical value
Index == 0x100: channel position
Index == 0x102: Operating hour of the device in hours
Index == 0x115: switching cycles of the contactors
Index == 0x120: number of disconnects at >700A
Index == 0x121: number of disconnects between 400A and 700A
ID-Name
Message ID
Data Length
Sender
Receiver
CH_SYSTEM_INFO_RESP
0x171 => Channel 1
0x172 => Channel 2
8 Byte
DSP
Remote
Byte
Bits
Values
Name
Description
0-1
0-15
-
Spec. value
Numerical value („unsigned short“ little-endian)
2-7
16-63
-
Placeholder
Unused, filled with 0x00