86
ID
ID-Name
Sender
Receiver
Data Length
Cycle Time
Channel Valid for Mode
0x5C2
CH_2_GET_PROT
DSP
Remote
8
-
2
Remote
A . B .
D e v i c e c o n t r o l
The remote control interface sends data for device control to the DSP
ID-Name
Message ID Data length
Sender
Receiver
DEV_CTRL 0x200
8 Byte
Remote
DSP
Byte Bits Area
Name
Description
0
0
0..1
E_STOP
Trigger SW-Interlock
2
0..1
Q_DEV_ERROR
Acknowledgement of device errors.
Clears all device errors in the register, not the error memory
3
Q_DEV_WARNING
Acknowledgement of device warnings.
Clears all device warnings in the register, not the warning memory
5
ISO_MONITORING_OFF
Deactivate isolation monitor
6
ISO2_MONITORING_OFF
Deactivate isolation monitor Ch2
7
ISO3_MONITORING_OFF
Deactivate isolation monitor Ch3
1
8
0..1
ISO4_MONITORING_OFF
Deactivate isolation monitor Ch4
10
0..1
CLR_ERR_WARN_BUFFER Clears all error and warning memories
2
16-17
CHANNEL_WIRING
0: Normal
=> normal wiring (single channel)
1: Parallel
=> parallel wiring of the channels
2: Serial
=> serial wiring of the channels
18-19 0..1
CLUSTER_MODE
Cluster Mode=> 0=None; 1=Single; 2=Cluster
20-21 0..1
CLUSTER_WIRING
Only during Cluster Operation
1: Parallel wiring
2:Seriell wiring
A . C .
D e v i c e S t a t u s
ID-Name
Message ID
Data Length
Sender
Receiver
Cycle Time
DEV_STATUS_QUERY
0x300
0 Byte
Remote
DSP
-
DEV_STATUS
0x100
8 Byte
DSP
Remote
Variable 1
Byte
Bits
Values
Name
Description
0
0
0..1
READY
Device is ready, no errors
1
0..1
AFE_ACTIVE
AC-DC-converters are active
2
0..1
I_LOCK
HW-Interlock has been triggered
3
0..1
E_STOP
SW-Interlock has been triggered
4
0..1
REMOTE
Remote control is active
5
0..1
ISO_OFF
State of isolation monitor
6
0..1
ERROR
error
7
0..1
WARNING
warning
1
8
0..1
DEV_ERROR
Device error
9
0..1
CH1_ERROR
Error Ch1
10
0..1
CH2_ERROR
Error Ch2
11
0..1
CH3_ERROR
Error Ch3