Manual ERS-BIC 160 kW V2.1
89
A . G .
C h a n n e l S t a t u s
ID-Name
Message ID
Data Length
Sender
Receiver
Cycle Time
CH_STATUS_QUERY
0x301 => Channel 1
0x302 => Channel 2
0 Byte
Remote
DSP
-
CH_STATUS
0x101 => Channel 1
0x102 => Channel 2
8 Byte
DSP
Remote
Variable 1
Byte Bits
Values
Name
Description
0
0
0..1
ON
Channel is activated
1
0..1
READY
Channel is ready to close the output contactors
2
0..1
SYNC
Charging of output capacitor is active
3
0..1
SW_STOP
Channel has been stopped
4
0..1
HV_RELAIS
State of output contactors
5
0..1
HV_ON
bit ‚HV_ON‘ of channel control
6
0..1
CH_ERROR
Channel error
7
0..1
CH_WARN
Channel warning
1
8-10
0..4
CTRL_MODE
0: not valid
1: CV-Mode
2: CC-Mode
4: CP-Mode
11-13
0..4
CTRL_MODE_ACT
1: CV-Act => voltage control active
2: CC-Act => current control active
4: CP-Act => power control active
14-15
0..2
OPER_MODE
Mode of operation, battery test mode:
0: PAUSE
1: DISCHARGE
2: CHARGE
Battery simulation:
0: BIDI
1: SINK
2: SOURCE
2
16-19
0..8
PAR_ID
Parameter set chosen
20
0..1
PAR_VALID
Parameter set valid
21
0..1
HW_STOP
Channel has been locked
22
0..1
ANALOG_VOLT
Analog voltage set value
23
0..1
ANALOG_CURRENT
Analog current set value
3
24
0..1
TEST_MODE
25
0..1
CH_ERR_CNT
Channel errors in the memory
26
0..1
CH_WARN_CNT
Channel warnings in the memory
27
0..1
RAMP_MODE_CTRL_V
State of ramp control
28
0..1
RAMP_MODE_CTRL_C
29
0..1
RAMP_MODE_CTRL_P
30
0..1
RS_422_SETVAL
Voltage and amperage controlled by RS422
31
0..1
CH_STOP
Channel has been stopped
4-5
32-47 0..65355 CH_ERR_CODE
Code of current channel error
6-7
48-63 0..65355 CH_WARN_CODE
Code of current channel warning