6.4 Device Operating Menus
60
Control-Parameters
Main Menu => Setup-Menu => Channel-Parameter DC-Output[x]:
In this menu you can configure the parameters of the control loops.
Table 32 Menu Control Parameter
Designation
Function
Voltage Loop Controller
Set the parameters for voltage control
Current Loop Controller
Set the parameters for current control
Power Loop Controller
Set the parameters for power control
P-Control
Proportional term of the control loop
I-Control
Integrating term of the control loop
Set Value Ramp
Definition of the set value ramp via voltage/time
(always same slope) or input of a time for the ramp
( always same time, ramp slope is calculated
depending on the set value)
Sub. Current Loop
Controller
Setting the parameters for the subordinate current
controller
Pre Control
Setting the parameters for the feed forward controller
Symmetry (password
protected)
Setting control parameters for subordinate balancing
controller in the output stage
Enable Parameter
Enable/Disable current set of parameters for use
ID 0 … ID 8
Select displayed parameter data set
ID 0 is the default parameter data set and cannot be
changed by the user
Fig. 52 Menu - Control Parameter