Manual ERS-BIC 160 kW V2.1
9
3.
TECHNICAL SPECIFICATION
Table 1 Dimension / Weight
Model series
ERS BIC 1200-1200/160 2C
Width /mm
2400
Height /mm
1960
Depth /mm
800
Weight /kg
1500
Table 2 Mains Connection
Mains Voltage
3x400 V
AC
Δ
±10% 47…63 Hz 3P/N/PE
Current consumption
3 x 280 A
Mains fuse internally
300 A/Phase (Circuit
breaker)
Mains fuse externally
>300 A
Mains connection/phase
1 x eyelet (bolt, Ø 10 mm)
Table 3 Output
Output Voltage V
nom
600
V (1200
V)
Output current I
nom
±600
A (±1200
A)
Discharge time (no load)
< 1 minute
Efficiency
> 93%
Output polarity
floating
1
Output terminal
Conductor rail, 4 x screwed connection, Ø 10
mm
Table 4 Display/Control
Output parameters
via touch screen
Configurations
via touch screen (password protected)
Service parameters
via touch screen (password protected)
Device ON
Rotary Switch
1
Optionally either the positive or negative side can be grounded.
⚠
Voltage to ground >500V possible!