8.5 Warnings
72
Table 38 Warnings
Code
Name
Description
0x0D
OPER_MODE_WARN
Charge or discharge mode is not set or is set
simultaneously
0x0E
CTRL_MODE_WARN
Control mode
0x0F
V_SET_BLOCK_WARN
Setting of new voltage is blocked (set point is
wrong)
0x10
P_DISTR_WARN
Power distribution
0x11
BATTERY_MODEL_WARN
Setting of new battery model is blocked
(channel is activated)
0x12
INVALID_PARA_WARN
forbidden parameter in CAN command
0x13
UNKNOWN_CMD_WARN
unknown CAN command (CAN-ID)
0x14
INVALID_CMD_WARN
forbidden CAN command
0x15
INIT_CH_PARA_WARN
forbidden channel parameter at initialization
0x16
INIT_DEV_PARA_WARN
forbidden device parameter at initialization
0x17
INIT_SERV_PARA_WARN
forbidden service parameter at initialization
0x18
INIT_OPER_DATA_WARN
forbidden operation mode parameter at
initialization
0x19
LOCKED_OPTION
option not released
0x1A
CONTROL_PARA_WARN
0x1B
REC_MSG_QUEUE_WARN
overflow CAN Input-buffer
0x1C
BLOCKED_CMD_WARN
command blocked, ERS currently busy
0x1D
HV_REL_LD_CNT_WARN
HV-Relay switched under load
0x1E
CODE_PASSWORD
0x1F
PAR_SER_MODE
wrong channel configuration for parallel or
serial mode
0x20
OUT_REL_LD_SWITCH
Relay counter has reached limit (1: 8000)
(2:
800) (3: 80) (4: 8) (5: 1)
0x21
SINGLE_RELAY
Relay switching sequence faulty
0x22
SHORTCUT_ON
Shortcut command still active
0x23
CAN_IO
CAN-IO module
0x24
FPGA_SW_VERSION
No FPGA version read
0x25
ISO_PROT1
limit 1 for Isolation monitor reached
0x26
WRONG_CMD
DSP send a FPGA off/on CMD in fast cycle
0x27
OUT_DIS_REL
Rapid discharge overloaded