3.5 Table 5 Interface
10
Table 5 Interface
Digital interface
[CAN-Bus]
Control of voltage, current and power
Monitoring of voltage, current power and device state
General control of device
Digital I/O
Potential free contacts / user specific
Table 6 Voltage Precision
Setting range
0… U
NOM
2
Reproducibility
≤
0.1% U
NOM
Voltage ramp-up time
(at step change in set
value)
< 1 ms [resistive load]
Control time at step in
load (10% to 90%)
≤
1 ms [resistive load]
Stability over an 8-hour
period (constant
conditions)
≤
0.1% U
NOM
Residual ripple
≤
0.2% U
NOM
for f = 0 … 1 MHz
Table 7 Current Precision
Setting range
0 A … I
NOM
Reproducibility
≤
0.1% I
NOM
Current ramp-up time
(at step change in set
value)
< 1 ms [resistive load]
Stability over an 8-hour
period (constant
conditions)
≤
0.1 % I
NOM
Temperature coefficient
≤
0.01% I
NOM
/K
Residual ripple
≤
0.4 % I
NOM
for f = 0 … 1 MHz
2
Reduced dynamics and current in regenerative operation <50V