10.3.3
Window trigger mode
For the window trigger mode, both levels are used. One of the levels has a dual
function, arm and trigger. The other level is used as a disarm level. To generate
a trigger, the trigger detector must be armed. This is done by crossing the arm/
trigger level in the opposite direction. Once armed, the trigger is generated by
crossing the arm/trigger level in the set direction, unless the disarm level has
been crossed after the arm level has been.
A
A
A
A
A/T
A/T
2
D
D
D
D
3
4
A/T
A/T
1
Figure 10.6:
Window trigger mode
A
Trigger
Diagrams
1
and
3
show the intended use of the window trigger mode, detecting
a dip in a repetitive signal. Diagrams
2
and
4
show alternatives, detecting a
peak pulse in a repetitive signal.
The Window trigger mode is very useful if a periodic signal is monitored and
GEN3i must be triggered on peak level changes. This mode is most effective
on uni
-
polar signals, e.g. a TTL level pulse train. For bi
-
polar signals, the dual
-
window trigger mode is more suited as described in the following section.
Relevant settings for this mode:
l
Mode: window
l
Primary level: any value within the input range
l
Secondary level: any value within the input range
l
Direction: positive or negative for primary level; secondary level is
automatically set to the opposite direction
l
Hysteresis: any relevant value is used for both levels.
GEN3i
150
I3763-3.1 en HBM: public
Содержание GEN3i
Страница 1: ...Portable Data Recorder GEN3i English User Manual I3763 3 1 en HBM public...
Страница 4: ...4 I3763 3 1 en HBM public...
Страница 51: ...33 46 7 70 IEC 61010 1 2010 IEC EN 50110 1 EN 50110 2 50 120 GEN3i I3763 3 1 en HBM public 51...
Страница 119: ...Figure 8 2 Acquistion control Detail A Record B Stop C Pause D Trigger GEN3i I3763 3 1 en HBM public 119...
Страница 822: ...Once the computer name has been entered correctly click Next Figure E 14 Computer name GEN3i 822 I3763 3 1 en HBM public...
Страница 1158: ...1158 I3763 3 1 en HBM public...
Страница 1159: ......