16 / 75
ba_aed104_8_e.doc
6.4 Command
overview
Command
PW
TDD 1
Function
Page
ADR
x
Adress
18
ASF
x
Digital filter
40
BDR
x
Baud rate
19
COF
x
Output format in MSV?
20
CRC
external checksum for legal for trade applic.
66
CSM
x
checksum in MSV status
24
DPW
Define password
47
ENU
Dimensional unit
50
ESR
Status
62
FMD
x
Filter mode
42
ICR
x
Measuring rate
43
IDN
Identification of transducer type and serial number
51
LDW
x
Zero point, user characteristic
32
LFT
x
Legal for trade applications
64
LIC
x
Linearization
57
LWT
x
Nominal value, user characteristic
33
MAV
Measured value, trigger function
58
MSV
Measured value output
36
NOV
x
x
Nominal value scaling
34
RES
Reset
49
S...
Select of AED in bus operation
26
SFA
x
Internal nominal value, factory characteristic
30
SPW
Password entry
48
STP
Messwertausgabe stoppen
39
STR
x
Switch bus termination resistors on/off
63
SZA
x
Stop measured value output
29
TAR
Tare mode
44
TAS
x
Gross/net switch-over
46
TAV
x
Tare value
45
TDD1/2
Store setting in EEPROM, read EEPROM
52
TDD0
x
Factory setting
52
TEX
x
Data delimiter for measured value output
25
TCR
Trade counter
65
TRC
x
Trigger setting
59
ZSE
x
Initial zero setting
55
ZTR
x
Automatic zero tracking
56
TDD1 – stored with TDD1 command
PW – protected by password with commands
DPW/SPW
The following commands result in no change to the AED setting:
ACL, ASS, CAL, COR, GRU (compatibility with other AED versions).