Smart Relay Load Wiring
A Smart Relay can be used to control either 115 or 230 VAC pool equipment. The relay is double pole
(makes/breaks both “legs” of 230V circuits or one "leg" of 115V circuits). Refer to the diagram below
for wire connections. Use the included Wiring Whip if the supplied electrical box will be mounted
within 6 ft of the power source. Red, black and green conductors are included for 230 VAC and a
white conductor is supplied if using 115 VAC input power. Use the included wire nuts for wiring con-
nections. Use proper threaded strain relief fittings for conduit attached to knockouts. After wiring is
complete, carefully insert the cover with connections into the box and secure.
Low Voltage Wiring
Note: There is a low voltage channel on the right side of the Hub's enclosure labeled on page 10
and shown on page 21. All low voltage wiring that exits the Hub must run through this channel. The
included foam gasket (page 21) should be used to seal the channels's exit after wiring is complete.
Do not run low voltage wiring through a knockout or with any high voltage wiring.
Hayward Variable Speed Pump (VSP) Wiring
A separate VSP pump manual has been included with the VS Omni. For low voltage communication
wiring information, refer to the pump manual.
Gray
Black
Black/White
Red
Red/White
Red
Red/White
Black
Black/White
Gray
Neutral
Load out
No Connection
No Connection
115 VAC
Load 2 out
Load 1 out
Line 1 in
230 VAC
Line in
Connect Gray &
Red to Line 2 in
Smart Relay
Wire Colors
13