Does Cleaner Have a Pump?
Select whether the cleaner has a dedicated pump. If so,
the VS Omni will turn this pump on when the cleaner is scheduled to run.
If Yes is selected:
What Type?
Select the type of pump used. The choices are Single Speed, Two
Speed and VSP.
If single speed or two speed pump is selected:
Which Relay is it Wired to?
If using a single speed or two speed
pump, you’ll be asked which relay(s) is wired to the pump. If a value is
already shown in the box(es), advance to the next screen. If no value
is shown, selecting the box will bring you to a table showing all de-
tected relays. Select the proper relay(s) from the table and touch the
Done button. The relay should now be shown in the box(es) and you
can advance to the next screen to continue the pump configuration.
If VSP is selected:
Which Hayward Unique Address?
If using a VSP for your cleaner
pump, you’ll be asked what is the Hayward Unique Address (HUA). If
a value is already shown in the box, advance to the next screen. If
no value is shown, selecting the box will bring you to a table show-
ing all detected devices. Select the proper HUA from the table and
touch the Done button. The address should now be shown in the
box and you can advance to the next screen to continue the VSP
configuration.
Pump Capacity -
Set the minimum and maximum RPM of the pump.
Refer to your pump manual for more information.
Permitted User Setting -
The VS Omni will automatically calculate
these values based on the minimum and maximum RPM that were
previously entered. They can be changed as desired.
Speed Presets -
Set the Low Pump Speed %, Medium Pump Speed
%, and High Pump Speed %, presets. These presets will be used
when setting schedules for your pump.
Does Cleaner have a Valve?
Select whether the cleaner requires a valve to change posi-
tion when in use.
If Yes is selected:
How Many?
Select how many valves are used for the cleaner.
Where is the Valve(s) Wired?
Selecting the box will bring you to a table show-
ing all detected low voltage relays. Select the relay(s) that is wired to the clean-
er valve(s), then advance. The valve(s) should now be shown in the box(es).
Advance to the next screen to continue.
33