Appendix C - ADM Run Screens Overview
3A2797ZAA
73
Home Screen, Night Mode
In Night Mode, the system will cycle on and off
periodically or turn on at a preset time. Entering night
mode will turn pumps and all conditioning zones off.
The circulation on/off cycle begins automatically upon
page 64.
Status Screen
The status screen provides all of the operational func
-
tionality of the Home screen except for operating mode
selection. Refer to the Home screen and operating
mode descriptions for information on this functionality.
In addition to the functionality provided by the Home
screen, the Status screen also provides material condi
-
tioning information and control.
Status Screen, Conditioning Control
This screen allows users to turn on and off heat zones
individually or all at once. When a zone is on it is
actively controlling temperature. Refer to the table
below for color code definitions.
To turn a single zone on/off:
1. Press
to enter the Conditioning Control screen.
2. Use the arrows keys to navigate to the desired
zone.
3. Press
to turn on the selected zone. When a
zone is on, the button will be selected. Press the
button again to turn off the zone.
To turn on/off all zones:
1. Press
to enter the Conditioning Control screen.
2. Press the
to turn on all zones. When one or
more zones are on, the button will be selected.
Press the button again to turn off all zones.
Zone
Setting
Color
Definition
OFF
Black
Dispense Disabled
Grey
Dispense Allowed
ON
Yellow
Dispense Disabled
Green
Dispense Allowed
All zones shown for reference. Only four zones may