Appendix E - System Events
3A2797ZAA
89
Appendix E - System Events
Event Code and
String
Triggers
EAA0-R: Prepoly
Refresh Started
While in night mode, the prepoly
refresh started.
EA0-R: Night Mode
Recirc On
While in night mode the system has
automatically entered a low circulation
mode and attempted to turn on all
enabled conditioning zones.
EA00-R: Disp.
Occurred (Shot #)
A dispense has occurred of the given
shot number.
EBA0-R: Prepoly
Refresh Complete
While in night mode, the prepoly
refresh completed successfully.
EB00-R: Stop Button
Pressed
The Red stop button was pressed on
the Advanced Display Module.
EBR0-R: Night Mode
Recirc Off
While in night mode the system has
automatically stopped the low circula
-
tion mode and turned off all condition
-
ing zones.
ECA1-R: Red Mate
-
rial SG Modified
The Red materials specific gravity was
modified.
ECB2-R: Blue Mate
-
rial SG Modified
The Blue materials specific gravity
was modified.
ECC1-R: Cavitation
Errors On
User has turned ON the Cavitation
Error Generation logic (default, and
recommended state for production
use) using the ADM module or Field
Bus interface.
ECC0-R: Cavitation
Errors Off
User has turned OFF the Cavitation
Error Generation logic (NOT
recommended for production use)
using the ADM module or Field Bus
interface. If turned OFF, and an HFR
pump does not completely fill, the
error will NOT be generated and the
ratio of the 2 materials may be correct.
This event will also be generated if set
when the HFR (or NVH) product
powers up.
ECD0-R: Mixer Motor
Disabled for Dispense
User has activated function (Pressed
“
” key) which may have negative
effects on future dispenses.
ECD1-R: Mixer Motor
Enabled for Dispense
User has re-enabled the mixer motor
for dispensing.
ECF0-R: Mixer Air
OFF for Dispense
User has activated function (Pressed
“
” key) which may have negative
effects on future dispenses.
ECF1-R: Mixer Air
Enabled for Dispense
User has re-enabled Air Nucleation for
dispensing.
ECGX: Dispense
Recipe Altered by
PLC
The rate (flow or pressure) or amount
has been altered by the controlling
CGM/PLC interface when the system
was in shot mode.
ECH0-R: Learn Mode
Executed
A learn mode calibration was success
-
fully completed.
EH00-R: Gel Timer
Dispense
The gel timer expired and the system
automatically took the gel shot.
EL00-R: System
Powered On
The System was powered on.
EM00-R: System
Powered Off
The System was powered off.
ENN0-R: Automatic
Cal. Performed
The system was successfully charac
-
terized with the Automatic calibration.
ENC1-R: Cal. Point 1
Weight Entered
A value for the first point in the three
point calibration was entered.
ENC2-R: Cal. Point 2
Weight Entered
A value for the second point in the
three point calibration was entered.
ENC4-R: Cal. Point 1
Weight Erased
The running average for point one of
the three point calibration was erased.
ENC5-R: Cal. Point 2
Weight Erased
The running average for point two of
the three point calibration was erased.
END0-R: Ratio Check
Dispense
A ratio check shot was dispensed
from the ratio check calibration
screen.
EQU1-R: Settings
Downloaded
The system settings were successfully
transferred from the ADM to a USB
drive.
EQU3-R: Language
Downloaded
The custom language file was suc
-
cessfully transferred from the ADM to
a USB drive.
EQU4-R: Language
Uploaded
The custom language file was suc
-
cessfully transferred from the USB
drive to the ADM.
EQU5-R: Logs Down
-
loaded
The Error/Event and Shot data logs
were successfully transferred from the
ADM to a USB drive.
ER01-R: Shot Count
Reset
A counter from the shot counters
maintenance page was erased
ER02-R: Seq. Posi
-
tion Count Reset
A counter from the sequence counters
maintenance page was erased
ERA1-R: Red Material
Volume Reset
The resettable totalizer for the Red
material volume was reset to zero.
ERB1-R: Blue Mate
-
rial Volume Reset
The resettable totalizer for the Blue
material volume was reset to zero.
ERA2-R: Red Material
Weight Reset
The resettable totalizer for the Red
material weight was reset to zero.
ERB2-R: Blue Mate
-
rial Weight Reset
The resettable totalizer for the Blue
material weight was reset to zero.
ERA3-R: Red Cycle
Count Reset
The resettable cycle counter for the
Red pump was reset to zero.
Event Code and
String
Triggers