Appendix D - ADM Error Codes
82
3A2797ZAA
P4H3
High
Accumulator
Pressure
AC Power Pack pressure too
high
Alarm
Accumulator Directional
Valve stuck in charge
position.
Check control line to Directional Valve. Replace
Directional Valve.
P6A1 Red Pressure
Sensor Fault The pressure sensor is
providing invalid/no pressure
readings
Alarm
Loose/bad connection Check to ensure the pressure transducer is properly
installed and all wires are properly connected
P6B2 Blue Pressure
Sensor Fault
Alarm
Bad sensor
Replace pressure transducer
No material in pump
Fill tanks
P6H1 Power Pack
Pressure
Sensor Fault
There is a failure with the AC
Power pack pressure sensor Alarm
Pressure sensor become
disconnected. Pressure
sensor wiring became
broken.
1. Replace pressure sensor.
2. Check wiring.
3. Possible failure with AC power FCm3 module.
P9H1 Accumulator
Charges too
Frequently
The AC Power pack charges
too often
Advisory
The time between
consecutive hydraulic
pressure charges in AC
power pack was too
short
1. Accumulator in the AC power pack needs
adjusted.
2. There is a possible leak in GX-16, L-head
dispense valve, a hose, manifold, etc. Fix
accordingly.
R1D0 Low Ratio
Alarm
Ratio monitor has detected an
out of ratio condition
Alarm
Material A to Material B
is out of ratio
Check feed system
R2D0 Low Ratio
Deviation
Deviation
R3D0 High Ratio
Deviation
R4D0 High Ratio
Alarm
Alarm
T1A2
Red Hose
Low Fluid
Temp.
Fluid temperature is below the
defined low alarm limit
Alarm
Tripped circuit breaker Visually check circuit breaker for a tripped condition
T1A3
Red Inline
Low Fluid
Temp.
T1A6
Red Tank
Low Fluid
Temp.
T1A7
Red Chiller
Low Fluid
Temp.
Cable unplugged/loose
power
Check for loose or disconnected wires or plugs
T1B1
Blue Inline
Low Fluid
Temp.
Tripped circuit breaker Visually check circuit breaker for a tripped condition
T1B4
Blue Hose
Low Fluid
Temp.
Low power
Measure voltage across input terminals on power line
filter. Voltage should measure between 190 and 264
Vac
T1B5
Blue Tank
Low Fluid
Temp.
Tripped circuit breaker Visually check circuit breaker for a tripped condition
T1B8
Blue Chiller
Low Fluid
Temp.
Bad heater(s)
Measure resistance of heater(s)
T20X
Dispensing
Disabled Low
Temp
Dispensing disabled because
of temperature
Advisory Temperature is out of
alarm limits
Check temperature alarm limits
Error
Code Error Name Error Description
Error
Type
Cause
Solution