Appendix D - ADM Error Codes
3A2797ZAA
79
D3A1 Setpoint
Exceeded
The set point was exceeded Deviation
System underwent a
change that caused a
large drop in restriction
(such as new orifices)
Erase learned System Data, found in the setup
screens under calibration
No material in pumps
Make sure the material lines are open and have
proper feed pressure
D4A1 Setpoint
Exceeded
The maximum cycles per
minute of the pump has been
exceeded
Deviation Restriction for the pump
is not sufficient
Increase the restriction or lower the set point
D5A1 Invalid Learn
Mode Data
This calibration lets the MCM
know where the ends of the
pump are. If the data gathered
during this process is outside
of normal parameters the
machine will operate with a
greatly reduced stroke.
Deviation
Recalibrate the machine Rerun the learn mode calibration
Loose/bad connection Check to ensure the pressure transducer is properly
installed and all wires are properly connected
Bad linear position
sensor
Verify pump moves to limits, if problem persists
replace linear position sensor
D6A1 Position
Sensor Fault
The linear position sensor is
returning data that should not
be possible during normal
operation
Alarm
Loose/bad connection to
linear position sensor
Check to ensure the linear position sensor is properly
installed and all wires are properly connected
Bad linear position
sensor
Replace linear position sensor
Linear position sensor
may be loose where
attached to pump
housing
Re-tighten the sensor and re-calibrate the machine
DDA1 Red Pump
Cavitation
Cavitation was detected on
the given pump
Deviation
Insufficient material
being supplied or
insufficient material
pressure on feed system
Verify that incoming ball valves are open
DDB2 Blue Pump
Cavitation
Verify that feed pumps are supplying material
Debris or packout in the
incoming fluid filter
Inspect filter for debris of filler packout and clean or
replace as necessary
DEH3 Soft Stop
Asserted
Soft Stop on AC Power Pack
has been pressed.
Alarm
User has pressed the
Red Soft Stop Button on
AC Power Pack.
Pull out Soft Stop button.
DFA1 Pump Not
Parked
The pump failed to reach the
park position
Deviation
Orifices blocked
Clear blockage
Hose blocked
Clear or replace hose as necessary
Dispense valve failed to
open
Check to make sure the dispense valve is properly
configured and connected to the MCM
DR6A Check Flow
Meter Red
Flow Meter has caused a fault Deviation
Cogs in flow meter are
not turning
Check that flow meter is matched to nominal pump
output
DR6B Check Flow
Meter Blue
Cable unplugged/loose
power
check of loose or disconnected wires or plugs
DSC0 Pumps Not
Defined
The type or size of the Red or
Blue material pumps have not
been defined
Alarm
Properly setup the
system
On the ADM go into the setup screens -> System->
then make sure that the pump type and size are set
(not --)
F1A0 Low Flow
Red
Flow is below the defined low
limit
Cogs in flow meter are
not turning
Check that flow meter is matched to nominal pump
output
F1B0 Low Flow
Blue
Check for loose or disconnected wires or plugs
F2A0 Low Flow
Red
Deviation
Check that flow meter is matched to nominal pump
output
F2B0 Low Flow
Blue
Cable unplugged/loose
power
Check for loose or disconnected wires or plugs
F3A0 High Flow
Red
Flow is above the defined low
limit
Cogs in flow meter are
turning rapidly
Check that flow meter is matched to nominal pump
output
F3B0 High Flow
Blue
F4A0 High Flow
Red
Alarm
F4B0 High Flow
Blue
Error
Code Error Name Error Description
Error
Type
Cause
Solution