Startup
42
3A2797ZAA
Startup
1. Check that all machine connections are setup. See
procedure, page 27.
2. Verify both PRESSURE RELIEF/DISPENSE valves
(SA, SB) are set to DISPENSE
.
3.
If dispense valve has a trigger safety lock,
engage
the trigger safety lock.
4. Open system fluid inlet valves and ball valves found
on the material tanks. As applicable, ball valves on
the material tanks include material supply, applica
-
tor return, and pressure relief. Check for leaks.
5. Press
to enable system. LED should be solid
green.
6. Navigate to Home Standby screen and press
to initiate auto startup.
7. Check that heat zones are on and temperatures are
on target. Check fluid pressure display. Refer to
on page 73 for more details.
8.
If dispense valve has a trigger safety lock,
disen
-
gage the trigger safety lock.
i. Equipment is ready to dispense.
To reduce the risk of personal injury, do not operate
HFR without all covers and shrouds in place.
ti9877a1
SA
SB
ti10442a1
LOCKED
ti10441a1
UNLOCKED