Appendix B - ADM Setup Screens Overview
64
3A2797ZAA
2. Press
to display the setpoint and alarm values
associated with that component.
3. Edit the setpoint and alarm values and then press
.
NOTE:
The high alarm and low alarm values must be at
least +/-9
°
F (5
°
C) than the material temperature value.
Conditioning Screen 3
This screen allows the user to configure Night Mode
operation. In Night Mode, the system will cycle on and
off periodically or turn on at a preset time. Press
and select periodic or time schemes.
When the system is in Night Mode and in an “On” cycle,
the system will circulate in low pressure. The installed
conditioning zones will be on and controlling to their
respective setpoints. When the system is in Night Mode
and in an “Off” cycle, the system will be idle. The
system will not be circulating and the conditioning
zones will not be actively controlling temperature. When
in Night Mode, supply tanks will not fill.
Periodic Night Mode Conditioning Screen
This screen allows the user to set the on and off times
of the machine in one minute intervals.
Time Based Night Mode Conditioning Screen
This screen allows the user to set a specific time each
day to turn the machine on or off. The times can be set
on or off by either each day separately, Monday
through Friday where each day has the same on or off
times, or Sunday through Saturday where each day has
the same on or off times.