Appendix G - Communications Gateway Module Installation Kit
3A2797ZAA
111
231
Dynamic Mixer
Speed
Set Point.
In RPM. Only valid if using Dynamic Mixer (Voltex) option.
Write
232
Read
234
Dynamic Mixer
Actual Speed
In RPM. Only valid if using Dynamic Mixer (Voltex) option.
Read
235
Dynamic Mixer Air
Nucleation On Time
In milli-second increments. Only valid if using Dynamic Mixer
(Voltex) option, and “Air Nucleation” turned ON (System #4 setup
screen).
Write
236
Read
237
Dynamic Mixer Air
Nucleation Off Time
In milli-second increments. Only valid if using Dynamic Mixer
(Voltex) option, and “Air Nucleation” turned ON (System #4 setup
screen).
Write
238
Read
239
Dynamic Mixer,
Motor Ramp Up
Time
In milli-second increments. Only valid if using Dynamic Mixer
(Voltex) option.
Write
240
Read
241
Dynamic Mixer, On/
Off State/ Request
1 = Motor On (read), or Turn ON Request (write). If sending a
Turn On Request, the system should be idle and Not dispensing.
Write
242
Read
243
Dynamic Mixer, Air
Nucleation On/ Off
State/ Request
1 = Air On (read), or Air ON Request (write). If sending a Turn On
Request, the system should be idle and Not dispensing.
Write
244
Read
251
Recirculation Flow
Rate Set Point
Set (Write) or get (read) the recirculation flow rate set point in in
0.01 cc/sec, 0.01 g/sec units (HFR Systems with Circulation
Valves Installed).
Write
252
Read
253
Low pressure
Circulation
Percentage
Set (Write) or get (read) the Low pressure Circulation flow rate
percentage (System #2 Setup screen). Values of 10 – 90 %
allowed (NVH Systems only).
Write
254
Read
260
Read System
Version
A 32-bit string in the format of 0xXXCCBBAA.
0xCC…Build Version
0xBB…Minor Version
0xAA…Major Version
Read
262
Read System Date
A 32-bit string in the format of 0xDDCCBBAA.
0xDD…Year (0x0D corresponds to 2013)
0xCC…Month (0x0A corresponds to October)
0xBB…Day
0xAA…Day of Week (0x01 Corresponds to Monday)
Read
271
Cavitation Errors
Disabled
Set (Write) or get (Read) if the Cavitation Error generation
logic is Disabled (= 1, not recommended for production use)
or Enabled (= 0, if logic is Active). Refer to “Cavitation Errors
Disabled” option on ADM Advanced #3 setup screen for
current state.
Write
272
Read
273-65, xxx
Reserved for Future
Use
-----
-----
Data Exchange
Pointer
Designation
Description
Comments, Data Element Descriptions
Read/
Write