Section 4 • Scheduled Maintenance Procedures
4 - 46
S-100 & S-105 & S-120 & S-125
Part No. 62401
REV B
January 2010
C-3
Perform Engine Maintenance -
Perkins Models
Engine specifications require that
this procedure be performed every
500 hours or 12 months, whichever
comes first.
Proper engine maintenance, following the engine
manufacturer's maintenance schedule, is essential
to good engine performance and service life. Failure
to perform the maintenance procedures can lead to
poor engine performance and component damage.
Required maintenance procedures and additional
engine information are available in the
Perkins 1004 User's Handbook
(Perkins part number TPD 1349E).
Perkins 1004 User's Handbook
Genie part number
61376
To access the engine:
1 Remove the engine tray retaining fastener
located under the engine tray. Swing the engine
tray out and away from the machine.
2 Install the fastener that was just removed
through the engine tray and into the engine tray
anchor hole in the turntable.
Crushing hazard. Failure to install
the fastener into the engine tray
anchor hole to secure the engine
tray from moving could result in
death or serious injury.
C-4
Replace the Engine Air Filter
Element
Engine specifications require that
this procedure be performed every
500 hours or 6 months, whichever
comes first.
Maintaining the engine air filter in good condition is
essential to good engine performance and service
life. Failure to perform this procedure can lead to
poor engine performance and component damage.
Perform this procedure with the
engine off.
1 Release the latches on the air cleaner cap.
Remove the end cap from the air cleaner
canister.
2 Remove the filter element.
3 Use a damp cloth to wipe the filter sealing
surface and the inside of the outlet tube. Make
sure that all contaminant is removed before the
filter is inserted.
4 Check new filter element gasket for damage
before installing.
5 Install the new filter element.
6 Install the end cap on the canister and secure.
Be sure the discharge slot is
pointing down.