Section 4 • Scheduled Maintenance Procedures
4 - 38
S-100 & S-105 & S-120 & S-125
Part No. 62401
REV B
January 2010
CHECKLIST
B
PROCEDURES
43 Activate the function enable/high RPM button
and attempt to raise the boom.
Result: The boom should not raise to more
than 11°.
Result: If the boom continues to raise, the
LSAX1ES or LSAX2ES switch are out of
adjustment or the wiring circuit is faulty and will
need to be replaced or repaired. See Repair
Section.
Bodily injury hazard. If the boom
raises to more than 11°, stop
immediately and lower the boom
until the boom is less than 11°.
Failure to lower the boom could
result in death or serious injury.
44 Remove the wire jumper installed in step 41 and
connect the deutsch connector to LSAX2ES.
Reverse Load Moment Switch,
LSB20LO
45 Activate the function enable/high RPM button
and fully retract the boom.
46 Activate the function enable/high RPM button
and lower the boom onto the boom rest pad and
continue to hold the boom lower function button
for 5 seconds.
47 Activate the function enable/high RPM button
and extend the boom until ">0" is present on the
display screen at the ground controls.
Result: The alarm should sound and "
REVERSE
LOAD
MOMENT
FAULT
" should be present on the
display screen at the ground controls.
Result: If the alarm does not sound or if "
REVERSE
LOAD
MOMENT
FAULT
" is not present on the display
screen at the ground controls, the LSB20LO
switch is out of adjustment or the wiring circuit
is faulty and will need to be replaced or repaired.
See Repair Section.
Bodily injury hazard. If the alarm
does not sound or if "
REVERSE
LOAD
MOMENT
FAULT
" is not present on the
display screen at the ground
controls, stop immediately and
fully retract the boom. Failure to
retract the boom could result in
death or serious injury.
48 Activate the function enable/high RPM button
and raise the boom to clear the alarm.
49 Activate the function enable/high RPM button
and lower the boom to the stowed position.
50 Turn the key switch to the
OFF
position.
Содержание S-100
Страница 1: ......