E-12
Perform Engine Maintenance -
Deutz Models
Engine specifications require that
this procedure be performed every
12000 hours.
Proper engine maintenance, following the engine
manufacturer's maintenance schedule, is essential
to good engine performance and service life. Failure
to perform the maintenance procedures can lead to
poor engine performance and component damage.
Required maintenance procedures and additional
engine information are available in the
Deutz F4L913 Operation Manual
(Deutz part number 0297 7341).
Deutz F4L913 Operation Manual
Genie part number
62446
To access the engine:
1 Remove the engine tray retaining fastener
located under the engine tray. Swing the engine
tray out and away from the machine.
2 Install the fastener that was just removed
through the engine tray and into the engine tray
anchor hole in the turntable.
Crushing hazard. Failure to install
the fastener into the engine tray
anchor hole to secure the engine
tray from moving could result in
death or serious injury.
E-13
Replace the Boom
Extend/Retract Cables
Genie specifications require that
this procedure be performed every
10
years.
The boom extend/retract cables are responsible for
the extension and retraction of the number 3 boom
tube on the S-100 and S-105, and the numbers 2
and 3 boom tubes on the S-120 and S-125.
Replacement of the boom extend/retract cables on
a regular basis is essential to good machine
performance and safe machine operation. The
boom extend/retract functions should operate
smoothlyand be free of hesitation, jerking and
unusual noise.
1 Replace the boom extend/retract cables. Refer
to Repair Procedure 4-5,
How to
Replace
the
Boom Extend/Retract Cables.