First Edition • First Printing
8 - 6
Genie S-120 & Genie S-125
Part No. 62401
Section 3 • Software
Screen
To Enter
Information Displayed
Lift function ramps
Press
on power on, then
Boom up/down ramp acceleration
press
Boom up/down ramp deceleration
Boom extend/retract ramp deceleration
Turntable rotate ramp acceleration
Turntable rotate ramp deceleration
Jib boom up/down ramp deceleration
Valve calibration
Press
on power on, then
Reset drive valve defaults
press
Reset boom up/down valve defaults
Reset boom extend/retract defaults
Reset turntable rotate valve defaults
Reset platform level valve defaults
Allow boom up/down speed calibration
Allow boom extend/retract speed calibration
Allow turntable rotate speed calibration
Reset drive joystick defaults
Reset boom up/down joystick defaults
Reset boom extend/retract joystick defaults
Reset turntable rotate joystick defaults
Reset steer joystick defaults
Options
Press
on power on, then
Limit boom height to 100 feet (30.5 m)
press
Limit boom height to 80 feet (24.4 m)
AC generator: no, regulated, none (0,1,2)
Alarm: no, motion, travel, decent, travel and
decent (0,1,2,3,4,5)
Lift/drive cut outs: no, drive cut out while not
stowed, Lifting, driving
Boom extend cut out if boom angle >5°
Auxilliary drive enable: yes, no
Proximity kill switch OR platform overload
sensing: none, prox, plat overload
Work light: yes, no
Flashing beacon: yes, no
Drive lights: yes, no
Steer mode change while driving: yes, no
DISPLAY MODULE
Содержание S-100
Страница 1: ......