Part No. 62401
Genie S-100 • S-105 • S-120 • S-125
7 - 73
Section 7 • Repair Procedures
First Edition • First Printing
5
Deutz models:
Disconnect the engine wiring
harness from the fuel shutoff solenoid at the
injector pump.
Deutz models
a
fuel shutoff solenoid
Cummins and Perkins models:
Disconnect
the wire from the fuel shutoff solenoid at the
injector pump.
Cummins models
a
fuel shutoff solenoid
Perkins models
a
fuel shutoff solenoid
6 Have another person crank the engine with the
starter motor for 15 seconds, wait 15 seconds,
then crank the engine an additional 15 seconds
or until the pressure reaches 250 psi / 17.2 bar.
Bodily injury hazard. Keep hands,
loose clothing and hair clear of all
moving engine parts while the
engine is cranking.
7
Deutz models:
Connect the engine wiring
harness to the fuel shutoff solenoid at the
injector pump.
Cummins and Perkins models:
Connect the
wire to the fuel shutoff solenoid at the injector
pump.
8 Start the engine and check for hydraulic leaks.
HYDRAULIC PUMPS
Содержание S-100
Страница 1: ......