20 Remove the cable-end block mounting plate
fasteners. Remove the cable-end block
mounting plate.
21 Remove the trunnion pin retaining fasteners.
22 Use a slide hammer to remove the trunnion pins
from the primary boom extension cylinder.
Use a
1
/
2 -
13 bolt thread on each
end of the slide hammer.
23 Attach a lifting strap from an overhead crane to
the lifting eye on the primary boom extension
cylinder.
24 Support and slide the primary boom extension
cylinder out of the boom assembly while guiding
the cables out of the boom and place it on a
structure capable of supporting it.
Crushing hazard. The primary
boom extension cylinder may
become unbalanced and fall when
it is removed from the boom if it is
not properly supported and
attached to the overhead crane.
Component damage hazard.
Cables can be damaged if they
are kinked, pinched or snagged
during removal.
During removal, the overhead
crane strap will need to be
adjusted for proper balancing.
BOOM COMPONENTS
14 Remove the lower external snap ring and washer
from the cable break limit switch actuator pivot
pin.
15 Remove the cable break actuator mounting plate
retaining fasteners. Remove the lower plate.
16 Remove the upper plate and actuator pivot pin.
Do not remove the cable break limit switch from
the mounting plate.
17 Push the cable break actuator and cables
towards the platform end of the boom
approximately 18 inches / 46 cm.
18 Remove the retaining fasteners from the red
cable adjustment locking bracket. Remove the
red locking bracket.
Bodily injury hazard. Failure to
install the red cable adjustment
locking bracket would allow the
cable mounting bolts to loosen
and fall out which could result in
death or serious injury.
a
red cable adjustment
locking bracket
19 Remove the two cable adjustment bolts.