Part No. 62401
Genie S-100 • S-105 • S-120 • S-125
7 - 23
Section 7 • Repair Procedures
First Edition • First Printing
7 Move the platform up and down by hand, so it
bounces approximately 2.5 to 5 cm / 1 to 2
inches. Allow the platform to settle.
Result: The alarm should be off. The platform
overload indicator light should be off at the
platform controls and there should be no error
message on the LCD display at the ground
controls. Proceed to step 8.
Result: The overload indicator lights are flashing
at the platform and ground controls, and the
alarm is sounding. Repeat this procedure
beginning with step 5.
There may be a 2 second delay
before the platform overload
indicator light and alarm responds.
8 Add an additional test weight to the platform.
S-105 and S-125- 10 lb / 4.5 kg
S-100 and S-120- 12 lb / 5.4 kg.
Result: The alarm should be sounding.
The platform overload indicator light should be
flashing at the platform controls and
“PLATFORM OVERLOAD” should be displayed
on the LCD screen at the ground controls.
Proceed to step 9.
Result: The alarm should be off. The platform
overload indicator light should be off at the
platform controls and there should be no error
message on the LCD display at the ground
controls. Remove the additional 10 lb / 4.5 kg
test weight. Repeat this procedure beginning
with step 6.
There may be a 2 second delay
before the platform overload
indicator light and alarm responds.
9 Test all machine functions from the platform
controls.
Result: All platform control functions should not
operate.
10 Turn the key switch to ground control.
11 Test all machine functions from the ground
controls.
Result: All ground control functions should not
operate.
12 Using a suitable lifting device, lift the test weight
off the platform floor.
Result: The alarm should be off. The platform
overload indicator light should be off at the
platform controls and there should be no error
message on the LCD display at the ground
controls.
There may be a 2 second delay
before the overload indicator lights
and alarm turn off.
13 Test all machine functions from the ground
controls.
Result: All ground control functions should
operate normally.
14 Turn the key switch to platform control.
15 Test all machine functions from the platform
controls.
Result: All platform control functions should
operate normally.
PLATFORM COMPONENTS
REV B