Part No. 62401
Genie S-100 • S-105 • S-120 • S-125
7 - 17
Section 7 • Repair Procedures
First Edition • First Printing
PLATFORM COMPONENTS
3 Lower the boom until the platform is resting on
the blocks just enough to support the platform.
Do not rest the entire weight of the
boom on the blocks.
4 Tag, disconnect and plug the hydraulic hoses
from the platform leveling cylinder at the
bulkhead fittings located inside the boom tube
at the platform end and connect them together
using a connector. Cap the bulkhead fittings on
the boom tube.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to
squirt or spray.
5 Remove the pin retaining fastener from
the platform leveling cylinder rod-end pivot pin.
Do not remove the pin.
6 Remove the external snap ring from the barrel-
end pivot pin. Do not remove the pin.
7 Support the platform leveling cylinder with a
suitable lifting device. Protect the cylinder rod
from damage.
8 Use a soft metal drift to remove the rod-end
pivot pin.
Crushing hazard. The platform
(S-100 and S-120 models) or jib
boom (S-105 and S-125 models)
will fall when the platform leveling
cylinder rod-end pivot pin is
removed if it is not properly
supported.
Crushing hazard. The platform
leveling cylinder will fall if it is not
properly supported when the rod-
end pivot pin is removed.
Component damage hazard. The
platform leveling cylinder rod can
become damaged if it is allowed to
fall.
9 Use a soft metal drift to remove the barrel-end
pivot pin.
10 Carefully pull the platform leveling cylinder out
of the boom.
Component damage hazard.
Hoses can be damaged if they are
kinked or pinched.