Part No. 62401
Genie S-100 • S-105 • S-120 • S-125
7 - 65
Section 7 • Repair Procedures
First Edition • First Printing
S-120 and S-125 models:
3 Raise boom until the protractor reads 67.5
degrees.
4 Loosen the mounting fasteners from the 68
degree proximity switch (LSB14AO).
5 Disconnect the deutsch connector from the 68
degree proximity switch (LSB14AO) and
connect an ohmmeter or continuity tester to
terminals 3 and 4 of the deutsch connector.
6 Adjust LSB14AO until the switch contacts just
open. While observing the digital protractor,
raise the boom until the switch contacts close,
then lower the boom until the switch contacts
open. Repeat the process until the switch
contacts open between 67.5 and 68 degrees.
7 Tighten the 68 degree proximity switch
(LSB14AO) mounting fasteners.
8 Lower the boom to 65.3 degrees.
9 Loosen the mounting fasteners from the 65
degree safety switch (LSB9AS).
10 Disconnect the deutsch connector from the 65
degree safety switch (LSB9AS) and connect an
ohmmeter or continuity tester to terminals 1 and
2, and to terminals 3 and 4 of the deutsch
connector.
11 Adjust LSB9AS until the switch contacts just
open. While observing the digital protractor,
raise the boom until the switch contacts close,
then lower the boom until the switch contacts
open. Repeat the process until the switch
contacts open between 65 and 65.5 degrees.
12 Tighten the 65 degree safety switch mounting
fasteners.
13 Lower the boom to 52.5 degrees.
All models:
14
S-100 and S-105 models:
Raise the boom to
52.5 degrees.
15 Loosen the mounting fasteners from the 53
degree proximity switch (LSB13AO).
16 Disconnect the deutsch connector from the 53
degree proximity switch (LSB13AO) and
connect an ohmmeter or continuity tester to
terminals 3 and 4 of the deutsch connector.
17 Adjust LSB13AO until the switch contacts just
open. While observing the digital protractor,
raise the boom until the switch contacts close,
then lower the boom until the switch contacts
open. Repeat the process until the switch
contacts open between 52.5 and 53 degrees.
18 Tighten the 53 degree limit switch mounting
fasteners.
19 Lower the boom to 50.3 degrees.
20 Loosen the mounting fasteners from the 50
degree safety switch (LSB8AS).
21 Disconnect the deutsch connector from the 50
degree safety switch (LSB8AS) and connect an
ohmmeter or continuity tester to terminals 1 and
2, and to 3 and 4 of the deutsch connector.
22 Adjust LSB8AS until the switch contacts just
open. While observing the digital protractor,
raise the boom until the switch contacts close,
then lower the boom until the switch contacts
open. Repeat the process until the switch
contacts open between 50 and 50.5 degrees.
LIMIT SWITCHES
Содержание S-100