GE
Heal
thcare
Direction 5643854-1EN,
Revision 9
O
p
ti
ma XR6
42
/XR
64
8 Pre-
In
st
a
lla
ti
on
Pag
e
13
0
S
ect
ion 3.0 - Sys
te
m
M
ast
er Int
e
rc
onne
ct Sch
e
mat
ic (MIS Ch
art
)
MADE
OTHER
APPROVALS
TITLE
FIRST MADE FOR:
REV
GE MEDICAL SYSTEMS
MILWAUKEE, WI
SHEET
OF
DD-MM-YY
REVISIONS
REV
MADE BY
DATE
PCN NO.
DESCRIPTION
CHECK
APPR
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
3
Everest II
2
2
GE HUALUN MEDICAL SYSTEM
DOC1484195
Wang Jian
J2 – Jedi CAN
J1 – System CAN
System Computer (Magic)
(Yellow)
RCIM2
KEYBOARD
Bar Code
Reader
MOUSE
USB
USB
USB
USB
MONITOR
VGA1
120VAC
External Ethernet
J4 – Ethernet – WS Dock
J5 – Ethernet – Table Dock
J6 Ethernet – Tether
GND stud
Hosp.
Network
System Cabinet
(Orange)
Wallbox
(No color)
Table
(Brown)
J4 – Table Ion Chamber
J2 – DPS 120VAC
J5 – Table CAN
J7- Ethernet – Table Dock
J6 – Table RT bus
GND stud
J1 – Table 220VAC
Wallstand
(Blue)
A1 J1 - Wallstand Ion Chamber
J5 – Wallstand DPS 120VAC
A1 J2 - Wallstand CAN
A6 J1 Ethernet – Wallstand Dock
GND stud – A7
J4 – Wallstand 120VAC
OTS
(No Color)
Stator, fan & SW – Tube 1 Stator
X-ray Tube Anode
OTS CAN – ALB L5
OTS PWR 120VAC
GND
X-ray Tube Cathode
TIB
(No Color)
Dongle
(No Color)
X-ray ON
Warning
Light
Door
Interlock
Switch
Room
Interface
Connector
Hospital
Vault
Mains
Hospital
380-480VAC
3 Phase Supply
P1
P2
P3
GND stud
GND stud
GND stud
GND stud
Jedi CAN – A25 J108
System CAN – A25 J107
Handswitch
J1-120VAC
7m
Tether Ethernet
Tether bkp
Shielding Cable is required
11767A
11768A
20100A
020003
11776A
120VAC
RCIM2
020065
020064
11763A
11764A
11760A
11761A
GND stud
RCIM – A25 J109
Table CAN – A25 J106
TIB PWR – A25 J7
Table Ion Chamber – A25 J81
DPS – A25 J4
TABLE PWR – A25 J3
Table RT – A25 J110
WS CAN – A25 J206
WS DPS – A25 J2
WS Ion Chamber – A25 J14
WS PWR – A25 J1
OTS CAN – A25 J41
Stator, fan & SW – A25 J42
OTS PWR – A25 J5
HV Tube Anode – A9
HV Tube Cathode – A9
11629A
11710A
11708A
11691A
11690A
11711A
11644A
020021
11755A
11756A
11757A
20100A
11632A
020045
11753A
020005
11754A
020003
11752A
020075
020077
Route through Cabinet
Control Room
120VAC – A25 J6
VGA2
USB
USB
USB
USB
OTS Console
J3-RS232
20101A
20102A
USB
UPS
11774A
11770A
5146500-7-ROHS
5146500-9-ROHS
5146500-12-ROHS
5160469-1
5160469-2
5146500-8
5146500-14-ROHS
5146500-13-ROHS
5146500-1
5146500-4
5368672-4
5146500-3
5146500-2
5146500-5
5336731-5
5307318-5
5368672-4
5336730-5
5336729-5
5336737-5
5336736-5
5146500-17
5341237-2
5146500-18
5336719
5336720
5146500-22
5341236
5402662
5393576-2
OptimaXR646 System MIS Chart
5389155-4
5336723
5368672-4
5368672-4
5336726
5336724
5336721
5412201
GND stud
GND stud
5419255
5411408
1
Fei xiaoyang
First revision as DOC
2
Fei xiaoyang
Aug 22, 2016
July 26, 2015
Updated
Li Jingliang
ALB Board
15-pin D-Sub
9-pin D-Sub
3
Li Jingliang
Apr 07, 2017
Correct J3 from 120VDC to PC RS232 to match design
System MIS chart with UPS
Pre-Install.book Page 130 Tuesday, January 30, 2018 2:36 PM