Page 5-30
MDE-4334C Atlas Start-up and Service Manual · April 2008
Pump Programming
Programming 8700 Series Units
Figure 5-11: Range Arm Setting
Range Arm
Range Arm Locator
4
To change the money unit setting, locate the lever control that is located above the variator
section on the same level as the price display. There are three available positions: 0.00, 1.00,
2.00. Remove the cotter pin, grasp the lever, and raise it slightly to clear the position locators.
Position the lever to the desired setting and release. Reinsert the cotter pin through the lever
and plate.
Note: If the lever will not move to the desired position, rotate the right hand money wheel
until the lever is free to move.
Figure 5-12: Insert Cotter Pin
5
If you have difficulty reaching the money shift lever when changing prices, remove the two
cap screws located over the tabs of the bezel assembly. Lift the bezel assembly upward and
remove it from the unit. When re-attaching the bezel to the dispensing unit, ensure that the top
inner edge of the bezel assembly slides into the “U” shaped channel located on the upper edge
of the dispensing unit.