Page 5-22
MDE-4334C Atlas Start-up and Service Manual · April 2008
Pump Programming
Programming 8800 Series Units
Function Code 10: Decimal/Comma Mode
Programs display format.
0 = Decimal point
1 = Decimal point, comma
Function Code 11: Pre-select Timeout
The customer must make a decision (other than the default) within the programmed time or the
unit will be de-authorized.
Function Coda 12: Pump Timeout
After you begin dispensing of fuel, if the idle time exceeds the programmed time, the unit will
terminate the sale.
0 = None
1 = 5 seconds
2 = 15 seconds
3 = 30 seconds
4 = 45 seconds
5 = 60 seconds
6 = 75 seconds
7 = 90 seconds
8 = 120 seconds
Function Code 13: Slowdown
This determines the time for which the unit will be in a slowdown mode during a preset sale.
Setting it for too short a time will result in you missing the target sale. Setting it for too long
will increase the time of completion the sale. This code is useful for preset problems.
0 = .070 gallons (.264 liters)
1 = .120 gallons (.454 liters)
2 = .170 gallons (.643 liters)
3 = .220 gallons (.833 liters)
4 = .270 gallons (1.02 liters)
5 = .320 gallons (1.21 liters)
6 = .370 gallons (1.40 liters)
7 = .420 gallons (1.59 liters)
8 = .470 gallons (1.78 liters)
9 = .520 gallons (1.97 liters)
Function Code 15: Zero PPU Pricing Option Enable
Allows dispensing of fuel with a “zero” PPU.
0 = Disabled
1 = Enabled
Function Code 16: Beeper Timeout
Used in conjunction with FC 12 to turn beeper off after a programmed period of time.
0 = None
1 = 5 seconds
2 = 15 seconds
3 = 30 seconds
4 = 45 seconds
5 = 60 seconds
6 = 75 seconds
7 = 90 seconds
8 = 120 seconds